The VI 800 Vortex Gas Flowmeter is offered
in co-operation with J-Tec Associates, U.S.A. A Vortex technology is employed by optimising a strut to produce vortices at lower flow, which are detected ultrasonically, detectors then detect.
The flowmeter is ideally suited to applications where gas flow is low and contains higher levels of moisture or particulates. Typical applications include Stack and Flare gases, Bio-gas and other Off-gases from sewage digesters and landfills.
| Unique ultrasonic vortex sensing | |
| Accuracy +/- 1% of full scale, Repeatability:+/- 0.5% | |
| No moving parts | |
| Drift free performance | |
| Adjustable insertion length accomodates a variety of pipe sizes | |
| 70:1 turndown ratio | |
| Low pressure drop |
| FlowRange | 0.6to 43 M/S |
| Operating Temperature | -40 to 150°C |
| Operating Pressure | -0.35 to 17 Bar (G) |
| Accuracy | +/- 1% full scale |
| Repeatability | +/- 0.5% of point |
| Input Power | 12 to 28 VDC @ 75 mA max |
| Output | Primary : 4-20 mA Secondary : Pulse Train (0 to 8 volts/ Square wave) Local Test : 0-5 Volt DC. |