Inline Turbine Flowmeter

inline turbine flowmeter

Rockwin turbine Flowmeters are designed to provide high order of performance, accuracy & reliability under the severest conditions encountered in Oil, Gas, Petrochemical, Aerospace and other industries.

These flowmeters are precise, reliable, rugged and built to international standards.

Sizes range from 5 to 300 mm with flanged end connections and 5 to 50 mm with threaded end connections. All flowmeters are individually calibrated on Rockwin's In-house Certified Calibration Laboratory.

http://www.rockwin.com/bullet.gif Linearity of +/- 0.50% of the reading
http://www.rockwin.com/bullet.gif Rangeability of 10:1
http://www.rockwin.com/bullet.gif Both for Liquid & Gas Applications
http://www.rockwin.com/bullet.gif SS construction
http://www.rockwin.com/bullet.gif Special end fittings also available

 

http://www.rockwin.com/bullet.gif

General Specifications

    PARAMETER METERS FOR LIQUIDS METERS FOR GASES
    Flow Range 0.03 to 2700 M3/Hr 0.88 to 8000 AM3/Hr
    Accuracy Linearity:+/- 0.5% over 10% to100% flow range. +/- 0.25% under specified conditions.              Repeatability:+/- 0.02% to +/- 0.05%on 95% confidence level +/- 1% over 10% to 100% flow range (inclusive of linearity and repeatability) 
    Max. Pressure  Threaded Meters- 250 kg/cm2 (4000 p.s.i.) Flanged meters- according to flange rating Threaded Meters- 250 kg/cm2 (4000 p.s.i.) Flanged meters- according to flange rating
    Pressure Drop Approx. 0.28 kg/cm2 (4 psi) at maximum flow (SG 1, Viscosity 1 cst) Approx. 1 inch w.g. at maximum flow (gas SG 1 )
    Temperature Range Tungsten Carbide/Stellite -50°C to +250°C Open Ball Bearings -50°C to +250°C (clean lubricating liquids only) Shielded Ball bearings -50°C to +150°C
    Electrical Connections MS type Amphenol connector Series 10 SL 3102 supplied with matting connector or terminal block, mounted in weather proof aluminium conduit box. MS type Amphenol connector Series 10 SL 3102 supplied with matting connector or terminal block, mounted in weather proof conduit box.
    Field Electronics  A range of Pre-amplifiers, F/I converters and local display electronics is available.

 

http://www.rockwin.com/bullet.gif

Model Selection        

 

Model No. Flow Range  M3/HR End Connection Threaded Ends End Connection Flanged ends Dimensions
A       D         C
1010 0.11 - 1.1 1/2" 1/2"/DN15 64     127       150
1015S  0.22 - 2.2 3/4" 3/4"/DN20 64     127       150
1015 0.4 - 4 3/4" 3/4"/DN20 64     127       150
1020 0.8 - 8 3/4" 3/4"/DN20 83     140        150
1025 1.6 - 16 1" 1"/DN25 88     152        200
1040 3.4 - 34 1.5" 1.5"/DN40 114    178        200
1050 6.8 - 68 2" 2"/DN50 132    197       200
1075 13.5 - 135 N/A 3"/DN80            254       200
1100 27 - 270 N/A 4"/DN100            356        300
1150 55 - 550 N/A 6"/DN150            368        300